ÅpenKunngjøring om konkurranse · 16VarerAMP / GPAnotice.framework_types.fa-wo-rcTED 115/2026

LC-MS/MS columns for Helse Bergen HF

Oppdragsgiver

Publisering (EUT)

17. juni 2026

Tilbudsfrist

3. juli 2026 10:00

Kontraktens varighet

48.0 måneder

Prosedyretype

Åpen anbudskonkurranse

Oppdragsgivers hjemsted

Vadsø (9811) — NO073

Beskrivelse

The objective of the procurement is to procure columns for use in LC-MS/MS analysis of urine, blood and spit. Tenders are wanted for the following columns: 1. Pursuit 3 C18 100 x 4.6mm 3 μm 2. Zorbax Eclipse XDB-C18 4.6x50mm 1.8μm 400 bar 3. Zorbax Eclipse XDB-C18, 3.0x50mm, 1.8μm 600bar 4. Zorbax Eclipse Plus C18 RHD, 2.1 x 50 mm, 1.8 μm 5. CarpenterLab Poroshell 120 Chiral-V, 2.7 μm, 2.1 x 150 mm The columns shall be used for routine determination of protoporfyrin IX in erytrocytes (1), porphytes in faeces, plasma and urine (2), MMA (3), steroid hormones in serum (4) and kiral separation of amphetamines in spit and urine (5). Other areas of use and sample matrix can be used. The columns are sometimes also used for research analyses, i.e. determination of substances in serum, plasma, urine and/or spinal fluid. A framework agreement shall be signed for the procurement of columns. See Annex 1 - Price Form for the estimated volume. The stated consumption/extent is an estimate for information to the tenderer and is not binding for the future contract volume. If different pack sizes can be offered (e.g. packs of three), the Contracting Authority would like to receive tenders for the pack size that will give the lowest unit price. See Annex 2 - Requirement Specification and Annex 1 - Price Form for further details.

CPV-koder

3800000038432200

Delkontrakter (1)

LOT-0001LC-MS/MS columns for Helse Bergen HF

The objective of the procurement is to procure columns for use in LC-MS/MS analysis of urine, blood and spit.  Tender offers are wanted on the following columns: 1. Pursuit 3 C18 100 x 4.6mm 3 μm 2. Zorbax Eclipse XDB-C18 4.6x50mm 1.8μm 400 bar 3. Zorbax Eclipse XDB-C18, 3.0x50mm, 1.8μm 600bar 4. Zorbax Eclipse Plus C18 RHD, 2.1 x 50 mm, 1.8 μm 5. aralallab Poroshell 120 Chiral-V, 2.7 μm, 2.1 x 150 mm Columns shall be used for routine determination of protoporfyrin IX in erytrocytes (1), porphytes in faeces, plasma and urine (2), MMA (3), steroid hormones in serum (4) and kiral separation of amphetamines in spit and urine (5). Other areas of use and sample matrix can be used. Columns will sometimes also be used for research analyses, i.e. determination of substances in serum, plasma, urine and/or spinal fluid. See Annex 1 - Price Form for the estimated volume. The stated consumption/extent is an estimate for information to the tenderer and is not binding for the future contract volume.  If different pack sizes can be offered (e.g. packs of three), the Contracting Authority would like to receive tenders for the pack size that will give the lowest unit price.    See Annex 2 - Requirement Specification and Annex 1 - Price Form for further details.

380000003843220048 måneder

Klagebehandling

Klageorgan

SYKEHUSINNKJØP HF — Vadsø

Flere kunngjøringer fra denne oppdragsgiveren